Moisture Contamination The Reeds
[ THE-224 / FLT-18 ]
UNITS: 4

MOISTURE CONTAMINATION
IN THE REEDS.

Ice forming at the expansion valve, acid odour, repeated driers blocking, cooling loss. REYDS engineers are on standby in The Reeds for immediate moisture contamination recovery.

069 268 0988 012 546 6670
[ THE-224 / FLT-18 DIAGNOSIS ]

Moisture Contamination — The Reeds recovery protocol.

CAUSE ANALYSIS — THE REEDS

  • 01Incomplete evacuation at last service
  • 02Wet refrigerant charge
  • 03Failed filter-drier
  • 04Leak pulling in moist air
  • 05System opened without nitrogen purge

RECOVERY PROTOCOL — THE REEDS

  • 01Moisture indicator and acid test
  • 02Filter-drier and strainer replacement
  • 03Triple evacuation with micron gauge
  • 04Nitrogen purge on all open work
  • 05Oil change if acid is confirmed
  • 06Moisture re-test after 48 hours
ZONE
The Reeds
SEVERITY
HIGH
RESPONSE
90 min
AVAILABILITY
24/7
[ THE-224 RELATED FAULTS ]

Other recovery services in The Reeds.

[ ADJACENT ZONES ]

Moisture Contamination — nearby zones.

24/7 STANDBY