High Discharge Pressure Three Rivers
[ THR-254 / FLT-19 ]
UNITS: 2

HIGH DISCHARGE PRESSURE
IN THREE RIVERS.

System cuts out on high pressure, discharge line too hot to touch, poor cooling. REYDS engineers are on standby in Three Rivers for immediate high discharge pressure recovery.

069 268 0988 012 546 6670
[ THR-254 / FLT-19 DIAGNOSIS ]

High Discharge Pressure — Three Rivers recovery protocol.

CAUSE ANALYSIS — THREE RIVERS

  • 01Restricted condenser airflow
  • 02Overcharged system
  • 03Non-condensables in the circuit
  • 04Fan cycling control failure
  • 05Recirculated hot air in the plant area

RECOVERY PROTOCOL — THREE RIVERS

  • 01Discharge and suction pressure analysis
  • 02Condenser airflow and fan check
  • 03Charge verification by weight
  • 04System evacuation to remove non-condensables
  • 05Head pressure control repair
  • 06Plant-room ventilation correction
ZONE
Three Rivers
SEVERITY
HIGH
RESPONSE
90 min
AVAILABILITY
24/7
[ THR-254 RELATED FAULTS ]

Other recovery services in Three Rivers.

[ ADJACENT ZONES ]

High Discharge Pressure — nearby zones.

24/7 STANDBY